Method 2529

Furfural by GC/FID


This method is for the determination of furfural. The sample is collected on XAD-2 sorbent tubes coated with 2-(hydroxymethyl)piperidine (2-HMP), desorbed with toluene followed by ultrasonication, and analyzed by GC/FID. The working range is 0.3 to 5.5 ppm (1.3 to 22 mg/m³) for a 12 L air sample. The method is suitable for the simultaneous determination of furfural and glutaraldehyde. Furfural reacts with 2-HMP to form a derivative during sampling. The sampling rate is limited by the speed of the derivitization reaction. Sampling rates greater than 0.05 L/min. may cause breakthrough due to an imcomplete reaction. NOTE: Method S17 is an alternate, less sensitive method for furfural, which uses bubbler collection and derivitization with Girard T reagent.


(NIOSH Issue 2: 15 August 1994)

Request-A-Quote

No Obligation Quotation for Analytical Services

If you would like us to provide a quote for laboratory analysis, just provide us with as much information as you can about your project (the more, the better) and we'll provide you a quote via email. As you are searching or browsing our Analytical Guide, you'll see the Request-A-Quote icon... just click on it to start the request process.
Request-A-Quote

Method Data

Hold Times, Preservatives, Preps, Collection, Analytical & Documentation
Holding Time:   At least 2 weeks from sampling to analysis if kept at 25°C
Preservatives:   Store at 25°C.
Required Preps:   Solid sorbent tube: 10% 2-(hydroxymethyl)piperidine coated XAD-2, 120 mg/60 mg, 10cm x 4mm ID
Collection Method:   Solid sorbent tube: 1 - 12 L @ 0.01 - 0.05 L/min.
Analytical Methodology:   GC/FID
Documentation:   2529

Analyte List*

Analyte Formula CAS Number Detection Limit
Furfural
C5H4O2
98-01-1
5
 µg

* The analytes and detection limits listed for each method represent the typical detection limits and analytes reported for that particular method. Keep in mind that analyte lists may vary from laboratory to laboratory. Detection limits may also vary from lab to lab and are dependent upon the sample size, matrix, and any interferences that may be present in the sample.